Availability: | |
---|---|
Quantity: | |
2200Max Series OTDR
3STelecom
3S 2200MAX Series OTDR (optical time domain reflectometer) is an intelligent new generation test and measurement OTDR. It is used for the installation and maintenance of fiber communication systems more accurately and efficiently. It is handy, lightweight and rugged enough for any outside plant environment. With a 7-inch, outdoor enhanced touchscreen, it provides a friendly user experience.
2200MAX is a full feature OTDR specially designed for layout and maintenance of trunk lines, branches, intercity, NLD, IT networking, power/railways/highways and OS plant communication requirements. The amazing dual battery design will never let a technician down, and all functions in one OTDR, like the OLS, OPM, VFL, fiber connector checking and USB tools, make every technician's job easier.
To detect link layer in the construction and installation of fiber optical network or proceed efficient maintenance and troubleshooting, 2200MAX OTDR series will definitely be your best assistant.
Key Features:
Integrated design, smart and rugged
7-inch, outdoor-enhanced touchscreen
PON online test module (1625nm/1650nm) optional
MMF test module (850/1350nm) optional
Built in optical light source (OLS) module
Built in optical power meter (OPM) module
Built in visual fault locator (VFL) module
Support multiple results analysis-segment return loss calculation, events return loss calculation, multicurve comparison, 4-point method loss calculation, 2-point method loss calculation
Dual-battery for heavy task testing
Applications:
FTTx test with PON networks
CATV network testing
Live fiber troubleshooting
Access network testing
LAN network testing
Metro network testing
Lab and factory testing
3S 2200MAX Series OTDR (optical time domain reflectometer) is an intelligent new generation test and measurement OTDR. It is used for the installation and maintenance of fiber communication systems more accurately and efficiently. It is handy, lightweight and rugged enough for any outside plant environment. With a 7-inch, outdoor enhanced touchscreen, it provides a friendly user experience.
2200MAX is a full feature OTDR specially designed for layout and maintenance of trunk lines, branches, intercity, NLD, IT networking, power/railways/highways and OS plant communication requirements. The amazing dual battery design will never let a technician down, and all functions in one OTDR, like the OLS, OPM, VFL, fiber connector checking and USB tools, make every technician's job easier.
To detect link layer in the construction and installation of fiber optical network or proceed efficient maintenance and troubleshooting, 2200MAX OTDR series will definitely be your best assistant.
Key Features:
Integrated design, smart and rugged
7-inch, outdoor-enhanced touchscreen
PON online test module (1625nm/1650nm) optional
MMF test module (850/1350nm) optional
Built in optical light source (OLS) module
Built in optical power meter (OPM) module
Built in visual fault locator (VFL) module
Support multiple results analysis-segment return loss calculation, events return loss calculation, multicurve comparison, 4-point method loss calculation, 2-point method loss calculation
Dual-battery for heavy task testing
Applications:
FTTx test with PON networks
CATV network testing
Live fiber troubleshooting
Access network testing
LAN network testing
Metro network testing
Lab and factory testing
General Specification
Size/Weight | 215x155x68mm / 1.1kg (Battery included) |
Display | 7 inch touch-sensitive TFT-LCD screen with LED Backlight 800x480 TFT |
Interface | 2xUSB port (Type A x 1, Type B x 1),4 x Optical port ( OPM port x1, VFL port x 1, OTDR ports x 2 ) |
Power Supply | Power supply AC/DC adapter, 10V(dc), 100V(ac) to 240V(ac), 50~60Hz |
Battery | 7.4V(dc)/2500mAh x 2pcs rechargeable lithium battery (with Air Traffic Certification) Operating time: 12 hours①, Telcordia GR-196-CORE Charging time: <3 hours (power off) |
Power Saving | Backlight -Common/Highlight/Power saving/Customized Auto Power Off -Never/1min/5min/10min/30min/60min |
Data Storage | Internal memory: 16GB (about 100,000 groups of curves) |
Language | Multi-language support including but not limited to Chinese, English, Spanish, French, Korean,Italian and Portuguese-contact us for availability of others) |
Environmental Conditions | Operating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation) Storage temperature and humidity: -20℃~+75℃, ≤95% (non-condensation) |
Accessories | Standard: Main unit, power adapter, Lithium battery, FC adapter, USB cord, User guide, CD disk, carrying case Optional: SC/ST/LC adapter, Bare fiber adapter |
OTDR Module
Pulse Width | Single mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs, 5μs, 10μs, 20μs Multi-mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs |
Distance Range | Single mode: 100m, 500m, 2km, 5km, 10km, 20km, 40km, 80km, 120km, 160km, 240km Multi-mode: 500m, 2km, 5km, 10km, 20km, 40km |
Sampling Resolution | Minimum 5cm |
Sampling Point | Maximum 256,000 points |
Linearity | ≤0.05dB/dB |
Averaging Time | 10s, 15s, 30s, Real Time, Customized |
Scale Indication | X axis: 4m~70m/div, Y axis: Minimum 0.09dB/div |
Distance Resolution | 0.01m |
Distance Accuracy | ±(1m+measuring distance×3×10-5+sampling resolution) (excluding IOR uncertainty) |
Reflectance Accuracy | Single mode: ±2dB, multi-mode: ±4dB |
IOR Setting | 1.2000~1.5999, 0.0001 step |
Units | km, miles, kfeet |
OTDR Trace Format | Telcordia universal, SOR, issue 2 (SR-4731) OTDR: User selectable automatic or manual set-up |
Testing Modes | Visual fault locator: Visible red light for fiber identification and troubleshooting Light source: Stabilized Light Source (CW, 270Hz, 1kHz, 2kHz output) Field microscope probe |
Fiber Event Analysis | -Reflective and non-reflective events: 0.01 to 1.99dB (0.01dB steps) -Reflective: 0.01 to 32dB (0.01dB steps) -Fiber end/break: 3 to 20dB (1dB steps) |
Other Functions | Real time sweep: 1Hz Averaging modes: Timed (1 to 3600 sec.) Live Fiber detect: Verifies presence communication light in optical fiber Trace overlay and comparison |
VFL Module (Visual Fault Locator)
Wavelength (±20nm) | 650nm |
Power | 10mw, CLASSIII B |
Range | 12km |
Connector | FC/UPC |
Launching Mode | CW/2Hz |
OPM Module (Optical Power Meter)
Wavelength Range (±20nm) | 800~1700nm |
Calibrated Wavelength | 850/1300/1310/1490/1550/1625/1650nm |
Test Range | Type A: -65~+5dBm (standard); Type B: -40~+23dBm (optional) |
Resolution | 0.01dB |
Accuracy | ±0.35dB±1nW |
Modulation Identification | 270/1k/2k Hz, P input≥-40dBm |
Connector | FC/UPC |
LS Module (Laser Source, as optional function)
Working Wavelength (±20nm) | Same as OTDR Wavelength |
Output Power | -5dBm±1dB |
Output Mode | CW/270/1k/2k Hz |
FM Module (Fiber Microscope, software is free, hardware inspection probe is sold separately)
Magnification | 400X |
Resolution | 1.0µm |
View of Field | 0.40×0.31mm |
Storage/working Condition | -18℃~35℃ |
Dimension | 235×95×30mm |
Sensor | 1/3 inch 2 million of pixel |
Weight | 150g |
USB | 1.1/2.0 |
Adapter② | SC-PC-F (For SC/PC adapter) FC-PC-F (For FC/PC adapter) LC-PC-F (For LC/PC adapter) 2.5PC-M (For 2.5mm connector, SC/PC, FC/PC, ST/PC) |
Ordering Information
Part Number③ | Testing Wavelength (MM: ±20nm, SM: ±10nm) | Dynamic Range (dB)④ | Event/Attenuation Dead-zone (m)⑤ |
2200MAX-A32 | 1310/1550 | 32/30 | 0.8/4 |
2200MAX-A35 | 1310/1550 | 35/33 | 0.8/4 |
2200MAX-A37 | 1310/1550 | 37/35 | 0.8/4 |
2200MAX-A40 | 1310/1550 | 40/38 | 0.8/4 |
2200MAX-A42 | 1310/1550 | 42/40 | 0.8/4 |
2200MAX-A45 | 1310/1550 | 45/43 | 0.8/4 |
2200MAX-B32 | 1625 | 32 | 0.8/4 |
2200MAX-B35 | 1625 | 35 | 0.8/4 |
2200MAX-B38 | 1625 | 38 | 0.8/4 |
2200MAX-AB35 | 1310/1550/1625 | 35/33/32 | 0.8/4 |
2200MAX-AB40 | 1310/1550/1625 | 40/38/37 | 0.8/4 |
2200MAX-AB42 | 1310/1550/1625 | 42/40/38 | 0.8/4 |
2200MAX-AB45 | 1310/1550/1625 | 45/43/40 | 0.8/4 |
2200MAX-C32 | 1650 | 32 | 0.8/4 |
2200MAX-C35 | 1650 | 35 | 0.8/4 |
2200MAX-C38 | 1650 | 38 | 0.8/4 |
2200MAX-AC35 | 1310/1550/1650 | 35/33/32 | 0.8/4 |
2200MAX-AC40 | 1310/1550/1650 | 40/38/37 | 0.8/4 |
2200MAX-AC42 | 1310/1550/1650 | 42/40/38 | 0.8/4 |
2200MAX-AC45 | 1310/1550/1650 | 45/43/40 | 0.8/4 |
2200MAX-AP35 | 1310/1490/1550 | 35/33/33 | 0.8/4 |
2200MAX-AP40 | 1310/1490/1550 | 40/36/38 | 0.8/4 |
2200MAX-M26 | 850/1300 | 22/26 | 2/6 |
2200MAX-AM32 | 1310/1550 & 850/1300 | 32/30 & 22/26 | 0.8/4 & 2/6 |
2200MAX-AM35 | 1310/1550 & 850/1300 | 35/32 & 22/26 | 0.8/4 & 2/6 |
MAX2200-AM40 | 1310/1550 & 850/1300 | 40/38 & 22/26 | 0.8/4 & 2/6 |
Optional Functions List
Part Number | Description | Spec & Notes |
2200MAX-XP-DW | GPS/GNSS/BDS | only one of them |
2200MAX-XP-LW | WiFi/Bluetooth | |
2200MAX-XP-WW | IoT module |
Notes:
① Typical, backlight off, sweeping halted at 25℃, 12 hours typical continuous testing.
② For more adapters, please contact us.
③ Part number including wavelength 1625nm, 1650nm and 1490nm are integrated with optical filter, which allow them to test PON network online (by using 1625nm, 1650nm or 1490nm wavelength) and will not interrupt the fiber signal.
④ Dynamic range is measured with maximum pulse width, averaging time is 3 minutes, SNR=1; The level difference between the RMS noise level and the level where near end back-scattering occurs.
General Specification
Size/Weight | 215x155x68mm / 1.1kg (Battery included) |
Display | 7 inch touch-sensitive TFT-LCD screen with LED Backlight 800x480 TFT |
Interface | 2xUSB port (Type A x 1, Type B x 1),4 x Optical port ( OPM port x1, VFL port x 1, OTDR ports x 2 ) |
Power Supply | Power supply AC/DC adapter, 10V(dc), 100V(ac) to 240V(ac), 50~60Hz |
Battery | 7.4V(dc)/2500mAh x 2pcs rechargeable lithium battery (with Air Traffic Certification) Operating time: 12 hours①, Telcordia GR-196-CORE Charging time: <3 hours (power off) |
Power Saving | Backlight -Common/Highlight/Power saving/Customized Auto Power Off -Never/1min/5min/10min/30min/60min |
Data Storage | Internal memory: 16GB (about 100,000 groups of curves) |
Language | Multi-language support including but not limited to Chinese, English, Spanish, French, Korean,Italian and Portuguese-contact us for availability of others) |
Environmental Conditions | Operating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation) Storage temperature and humidity: -20℃~+75℃, ≤95% (non-condensation) |
Accessories | Standard: Main unit, power adapter, Lithium battery, FC adapter, USB cord, User guide, CD disk, carrying case Optional: SC/ST/LC adapter, Bare fiber adapter |
OTDR Module
Pulse Width | Single mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs, 5μs, 10μs, 20μs Multi-mode: 3ns, 5ns, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1μs, 2μs |
Distance Range | Single mode: 100m, 500m, 2km, 5km, 10km, 20km, 40km, 80km, 120km, 160km, 240km Multi-mode: 500m, 2km, 5km, 10km, 20km, 40km |
Sampling Resolution | Minimum 5cm |
Sampling Point | Maximum 256,000 points |
Linearity | ≤0.05dB/dB |
Averaging Time | 10s, 15s, 30s, Real Time, Customized |
Scale Indication | X axis: 4m~70m/div, Y axis: Minimum 0.09dB/div |
Distance Resolution | 0.01m |
Distance Accuracy | ±(1m+measuring distance×3×10-5+sampling resolution) (excluding IOR uncertainty) |
Reflectance Accuracy | Single mode: ±2dB, multi-mode: ±4dB |
IOR Setting | 1.2000~1.5999, 0.0001 step |
Units | km, miles, kfeet |
OTDR Trace Format | Telcordia universal, SOR, issue 2 (SR-4731) OTDR: User selectable automatic or manual set-up |
Testing Modes | Visual fault locator: Visible red light for fiber identification and troubleshooting Light source: Stabilized Light Source (CW, 270Hz, 1kHz, 2kHz output) Field microscope probe |
Fiber Event Analysis | -Reflective and non-reflective events: 0.01 to 1.99dB (0.01dB steps) -Reflective: 0.01 to 32dB (0.01dB steps) -Fiber end/break: 3 to 20dB (1dB steps) |
Other Functions | Real time sweep: 1Hz Averaging modes: Timed (1 to 3600 sec.) Live Fiber detect: Verifies presence communication light in optical fiber Trace overlay and comparison |
VFL Module (Visual Fault Locator)
Wavelength (±20nm) | 650nm |
Power | 10mw, CLASSIII B |
Range | 12km |
Connector | FC/UPC |
Launching Mode | CW/2Hz |
OPM Module (Optical Power Meter)
Wavelength Range (±20nm) | 800~1700nm |
Calibrated Wavelength | 850/1300/1310/1490/1550/1625/1650nm |
Test Range | Type A: -65~+5dBm (standard); Type B: -40~+23dBm (optional) |
Resolution | 0.01dB |
Accuracy | ±0.35dB±1nW |
Modulation Identification | 270/1k/2k Hz, P input≥-40dBm |
Connector | FC/UPC |
LS Module (Laser Source, as optional function)
Working Wavelength (±20nm) | Same as OTDR Wavelength |
Output Power | -5dBm±1dB |
Output Mode | CW/270/1k/2k Hz |
FM Module (Fiber Microscope, software is free, hardware inspection probe is sold separately)
Magnification | 400X |
Resolution | 1.0µm |
View of Field | 0.40×0.31mm |
Storage/working Condition | -18℃~35℃ |
Dimension | 235×95×30mm |
Sensor | 1/3 inch 2 million of pixel |
Weight | 150g |
USB | 1.1/2.0 |
Adapter② | SC-PC-F (For SC/PC adapter) FC-PC-F (For FC/PC adapter) LC-PC-F (For LC/PC adapter) 2.5PC-M (For 2.5mm connector, SC/PC, FC/PC, ST/PC) |
Ordering Information
Part Number③ | Testing Wavelength (MM: ±20nm, SM: ±10nm) | Dynamic Range (dB)④ | Event/Attenuation Dead-zone (m)⑤ |
2200MAX-A32 | 1310/1550 | 32/30 | 0.8/4 |
2200MAX-A35 | 1310/1550 | 35/33 | 0.8/4 |
2200MAX-A37 | 1310/1550 | 37/35 | 0.8/4 |
2200MAX-A40 | 1310/1550 | 40/38 | 0.8/4 |
2200MAX-A42 | 1310/1550 | 42/40 | 0.8/4 |
2200MAX-A45 | 1310/1550 | 45/43 | 0.8/4 |
2200MAX-B32 | 1625 | 32 | 0.8/4 |
2200MAX-B35 | 1625 | 35 | 0.8/4 |
2200MAX-B38 | 1625 | 38 | 0.8/4 |
2200MAX-AB35 | 1310/1550/1625 | 35/33/32 | 0.8/4 |
2200MAX-AB40 | 1310/1550/1625 | 40/38/37 | 0.8/4 |
2200MAX-AB42 | 1310/1550/1625 | 42/40/38 | 0.8/4 |
2200MAX-AB45 | 1310/1550/1625 | 45/43/40 | 0.8/4 |
2200MAX-C32 | 1650 | 32 | 0.8/4 |
2200MAX-C35 | 1650 | 35 | 0.8/4 |
2200MAX-C38 | 1650 | 38 | 0.8/4 |
2200MAX-AC35 | 1310/1550/1650 | 35/33/32 | 0.8/4 |
2200MAX-AC40 | 1310/1550/1650 | 40/38/37 | 0.8/4 |
2200MAX-AC42 | 1310/1550/1650 | 42/40/38 | 0.8/4 |
2200MAX-AC45 | 1310/1550/1650 | 45/43/40 | 0.8/4 |
2200MAX-AP35 | 1310/1490/1550 | 35/33/33 | 0.8/4 |
2200MAX-AP40 | 1310/1490/1550 | 40/36/38 | 0.8/4 |
2200MAX-M26 | 850/1300 | 22/26 | 2/6 |
2200MAX-AM32 | 1310/1550 & 850/1300 | 32/30 & 22/26 | 0.8/4 & 2/6 |
2200MAX-AM35 | 1310/1550 & 850/1300 | 35/32 & 22/26 | 0.8/4 & 2/6 |
MAX2200-AM40 | 1310/1550 & 850/1300 | 40/38 & 22/26 | 0.8/4 & 2/6 |
Optional Functions List
Part Number | Description | Spec & Notes |
2200MAX-XP-DW | GPS/GNSS/BDS | only one of them |
2200MAX-XP-LW | WiFi/Bluetooth | |
2200MAX-XP-WW | IoT module |
Notes:
① Typical, backlight off, sweeping halted at 25℃, 12 hours typical continuous testing.
② For more adapters, please contact us.
③ Part number including wavelength 1625nm, 1650nm and 1490nm are integrated with optical filter, which allow them to test PON network online (by using 1625nm, 1650nm or 1490nm wavelength) and will not interrupt the fiber signal.
④ Dynamic range is measured with maximum pulse width, averaging time is 3 minutes, SNR=1; The level difference between the RMS noise level and the level where near end back-scattering occurs.