Availability: | |
---|---|
Quantity: | |
OCID-C
3STelecom
OCID-C Outdoor Optical Cable Identifier Integrated with OTDR, OLS, OPM, VFL and Loss Testing Function |
OCID-C Series Optical Cable Identifier is an intelligent instrument designed for the construction and maintenance of optical cable lines in optical communication system. In view of the complex wiring environment and the difficulty of locating faults during the construction and long-term use of optical cables, OCID-C series can provide fast, effective and accurate fault solutions. When the target optical cable is bent or shaken, the optical cable identifier instrument can quickly capture the vibration signal and display it through waveform and sound, so as to locate the target optical cable quickly.
OCID-C series provides the simplest method for Telecommunication engineers and technicians to track and identify the target optical fiber or cable clearly. Optical cable identifier instrument has the advantages of friendly interface, simple and practical, non-toxic and harmless, and does not damage optical cable. It is suitable for accurate identification of optical cable in the environment of manhole, tunnel, overhead, pipeline and so on. It is a new instrument tailored for optical cable construction, acceptance and operation and maintenance technicians.
Features:
Easily identify all kinds of break point, APC or UPC optical cable end
Integrating full-function OTDR, LS, OPM, VFL and optical loss test functions
One-key intelligent test and without tedious parameter settings
Single fiber test, no looping at the distal end
Multi-functional test platform to meet deversified test requirements
5.6 inch color LCD touch screen, button/ touch dual operation
Locate the target optical cable clear and easy to understand through audio or visual signals in complex environment
8. Intelligent optical fiber link detection, graphical results show, clear and easy to understand
Specifications:
Optical Cable Identifier (OCID) Module | |
Measurement Method | Single Fiber (No loop) |
Wavelength | 1550nm |
Test Distance | 60km |
Cable Loss | ≤14dB @60km, ≤24dB @120km |
Waveform Display | Support (in Real Time) |
Audio Sound | Support (in Real Time) |
Initial Blind Zone | No Blind Zone |
SNR | > 10dB |
Fiber Type | 9/125 Single Mode Fiber |
Connector | SC/APC and FC/UPC |
OTDR Module | |
Wavelength | 1550nm |
Dynamic Range | 30dB |
Pulse Width | 5ns,10ns,50ns,80ns,160ns,320ns,500ns,800ns,1μs,3μs,5μs,8μs,10μs, 20μs |
Distance Range | 500m,1km, 2km, 4km, 8km, 16km, 32km, 64km, 128km, 256km |
Sampling Resolution | 0.05 to 16m |
Sampling Point | 16k to 128k points |
Linearity | ≤0.2dB/dB |
Averaging Time | Setting by user |
Scale Indication | X axis: 4~70m/div, Y axis: 0.09~5dB/div |
Distance Accuracy | ±(1m+measuring distance×3×10^-5+sampling resolution) ( excluding IOR uncertainty) |
Loss Threshold | 0.01dB |
Loss Resolution | 0.001dB |
Distance Resolution | 0.01m |
IOR Setting | 1.0~2.0, 0.0001 step |
Units | km |
OTDR Trace Format | Telcordia universal, SOR, issue 2(SR-4731) |
OLS Module | |
Wavelength | 1550nm |
Output Power | > -5dBm |
Output Mode | CW/270/330/1k/2k Hz |
OPM Module | |
Wavelength | 850/980/1300/1310/1490/1550/1625/1650nm |
Test Range | -50~+ 26dBm (default) |
Accuracy | ±0.35dB±1nW |
Modulation | 270/330/1k/2k Hz, Pi≥-40dBm |
VFL Module | |
Wavelength | 650nm |
Output Power | 1mw, CLASSIII A |
Test Range | 5km |
Launching Mode | CW/1Hz/2Hz |
Adapter Type | 2.5mm Universal Adapter for FC SC ST Connectors |
General Information | |
Size/Weight | 227x160x70mm/ 1.5kg |
Display | 5.6 Inch Colorful LCD Touch Screen |
Interface | USB, TF Card Port, Rj45 Port, OTDR port, VFL port, Power Meter Port, Charging Port |
Power Supply | Input: 100V(ac) to 240V(ac), 50~60Hz; Output: 12~19V(DC)1.5A; 5000mAh/7.4V Lithium battery |
Working Time | >8 hours; Charging < 5 hours |
Power Saving | Intelligent power management Auto power off: Never/1min/5min/10min/30min/60min |
Data Storage | TF Card (8G Max) |
Language | English in Default |
Environmental Conditions | Operating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation) Storage temperature and humidity: -40℃~+70℃, ≤95% (non-condensation) |
OCID-C Outdoor Optical Cable Identifier Integrated with OTDR, OLS, OPM, VFL and Loss Testing Function |
OCID-C Series Optical Cable Identifier is an intelligent instrument designed for the construction and maintenance of optical cable lines in optical communication system. In view of the complex wiring environment and the difficulty of locating faults during the construction and long-term use of optical cables, OCID-C series can provide fast, effective and accurate fault solutions. When the target optical cable is bent or shaken, the optical cable identifier instrument can quickly capture the vibration signal and display it through waveform and sound, so as to locate the target optical cable quickly.
OCID-C series provides the simplest method for Telecommunication engineers and technicians to track and identify the target optical fiber or cable clearly. Optical cable identifier instrument has the advantages of friendly interface, simple and practical, non-toxic and harmless, and does not damage optical cable. It is suitable for accurate identification of optical cable in the environment of manhole, tunnel, overhead, pipeline and so on. It is a new instrument tailored for optical cable construction, acceptance and operation and maintenance technicians.
Features:
Easily identify all kinds of break point, APC or UPC optical cable end
Integrating full-function OTDR, LS, OPM, VFL and optical loss test functions
One-key intelligent test and without tedious parameter settings
Single fiber test, no looping at the distal end
Multi-functional test platform to meet deversified test requirements
5.6 inch color LCD touch screen, button/ touch dual operation
Locate the target optical cable clear and easy to understand through audio or visual signals in complex environment
8. Intelligent optical fiber link detection, graphical results show, clear and easy to understand
Specifications:
Optical Cable Identifier (OCID) Module | |
Measurement Method | Single Fiber (No loop) |
Wavelength | 1550nm |
Test Distance | 60km |
Cable Loss | ≤14dB @60km, ≤24dB @120km |
Waveform Display | Support (in Real Time) |
Audio Sound | Support (in Real Time) |
Initial Blind Zone | No Blind Zone |
SNR | > 10dB |
Fiber Type | 9/125 Single Mode Fiber |
Connector | SC/APC and FC/UPC |
OTDR Module | |
Wavelength | 1550nm |
Dynamic Range | 30dB |
Pulse Width | 5ns,10ns,50ns,80ns,160ns,320ns,500ns,800ns,1μs,3μs,5μs,8μs,10μs, 20μs |
Distance Range | 500m,1km, 2km, 4km, 8km, 16km, 32km, 64km, 128km, 256km |
Sampling Resolution | 0.05 to 16m |
Sampling Point | 16k to 128k points |
Linearity | ≤0.2dB/dB |
Averaging Time | Setting by user |
Scale Indication | X axis: 4~70m/div, Y axis: 0.09~5dB/div |
Distance Accuracy | ±(1m+measuring distance×3×10^-5+sampling resolution) ( excluding IOR uncertainty) |
Loss Threshold | 0.01dB |
Loss Resolution | 0.001dB |
Distance Resolution | 0.01m |
IOR Setting | 1.0~2.0, 0.0001 step |
Units | km |
OTDR Trace Format | Telcordia universal, SOR, issue 2(SR-4731) |
OLS Module | |
Wavelength | 1550nm |
Output Power | > -5dBm |
Output Mode | CW/270/330/1k/2k Hz |
OPM Module | |
Wavelength | 850/980/1300/1310/1490/1550/1625/1650nm |
Test Range | -50~+ 26dBm (default) |
Accuracy | ±0.35dB±1nW |
Modulation | 270/330/1k/2k Hz, Pi≥-40dBm |
VFL Module | |
Wavelength | 650nm |
Output Power | 1mw, CLASSIII A |
Test Range | 5km |
Launching Mode | CW/1Hz/2Hz |
Adapter Type | 2.5mm Universal Adapter for FC SC ST Connectors |
General Information | |
Size/Weight | 227x160x70mm/ 1.5kg |
Display | 5.6 Inch Colorful LCD Touch Screen |
Interface | USB, TF Card Port, Rj45 Port, OTDR port, VFL port, Power Meter Port, Charging Port |
Power Supply | Input: 100V(ac) to 240V(ac), 50~60Hz; Output: 12~19V(DC)1.5A; 5000mAh/7.4V Lithium battery |
Working Time | >8 hours; Charging < 5 hours |
Power Saving | Intelligent power management Auto power off: Never/1min/5min/10min/30min/60min |
Data Storage | TF Card (8G Max) |
Language | English in Default |
Environmental Conditions | Operating temperature and humidity: -10℃~+50℃, ≤95% (non-condensation) Storage temperature and humidity: -40℃~+70℃, ≤95% (non-condensation) |